Planar UltraRes L Series User Manual page 34

Hide thumbs Also See for UltraRes L Series:
Table of Contents

Advertisement

Setting
Command Code
Save
SAVE.
2314 !
Diagnostics
DIAGNOSTICS
Schedule
SCHEDULE
2100 =?
Schedule
SCHEDULE.
2102 =?
Action
ACTION
Schedule
SCHEDULE.DAY
2101 =?
Day
Schedule
SCHEDULE.
2104 ?
Description
DESCRIPTION
Planar UltraRes L Series RS232 User Manual
020-1428-00A
34
Modifiers
Location
0 = USB
Mod 1: Slot
Unsigned int
1-20
Mod 2: Parameter
0 = FREQ
1 = MINUTE
2 = HOUR
3 = DAY
4 = ACTION
5 = DATA
6 = ENABLE
[None = ALL]
Slot
0 = TURN.ON
1-20
1 = TURN.OFF
2 = RECALL
3 = PANEL.
BRIGHTNESS
Slot
0 = MON
1-20
1 = TUE
2 = WED
3 = THU
4 = FRI
5 = SAT
6 = SUN
Slot
String
1-20
Example
No
SAVE.DIAGNOSTICS(USB)
SAVE.DIAGNOSTICS(USB)@ACK
Yes
[Change the action for event 3 to
Turn On]
SCHEDULE(3, ACTION)=0
SCHEDULE(3, ACTION):0
Yes
[Change the action for event 3 to
Turn On]
SCHEDULE.ACTION(3)=TURN.ON
SCHEDULE.ACTION(3):TURN.ON
Yes
[Change the day for event 3 to
Monday]
SCHEDULE.DAY(3)=MON
SCHEDULE.DAY(3):MON
Yes
[Read the schedule description
string for event 3]
SCHEDULE.DESCRIPTION(3)?
SCHEDULE.DESCRIPTION(3):
"Daily 08:15 Backlight 25"
Notes
See Main -> Advanced
Settings -> System
Settings -> Save
Diagnostics to USB.
See Main -> Advanced
Settings -> Schedule ->
Set Event 1-20.
Reference the Schedule
Action, Schedule Day and
Schedule Frequency
settings for operand
values.
See Main -> Advanced
Settings -> Schedule ->
Set Event 1-20 -> Action.
See Main -> Advanced
Settings -> Schedule ->
Set Event 1-20 -> Day.
This is the string used for
the schedule slots in the
Main -> Advanced
Settings -> Schedule
menu.
Page | 34

Advertisement

Table of Contents
loading

This manual is also suitable for:

Url136-t

Table of Contents