1.4 General Specifications

1.4.1 Electrical Specifications

Primary power input
Table 1-10. Primary Power Specifications
Item
100-120 V model
Rated power supply voltage
100 to 120 VAC
Input voltage range
90 to 132 VAC
Rated current
Rated frequency
Input frequency range
Insulation resistance
Energy conservation
Stylus C110/C120/D120
Approx. 15 W
(ISO10561 Letter Pattern)
WorkForce 30/EPSON
Printing
Stylus OFFICE B30/T30/
Power
T33/ME OFFICE 70
consumption
Approx. 15 W
(ISO/IEC24712 Pattern)
Sleep
Approx. 2.0 W
Off
Approx. 0.2 W
Note : If the printer is not operated for more than three minutes, the printer shifts into the
standby mode and reduces the current to the motor to conserve power.
PRODUCT DESCRIPTION
220-240 V model
220 to 240 VAC
198 to 264 VAC
0.6 A
0.3 A
50 to 60 Hz
49.5 to 60.5 Hz
3000 V (for one minute)
International Energy Star Program compliant
Stylus C110/C120/D120
Approx. 15 W
(ISO10561 Letter Pattern)
WorkForce 30/EPSON
Stylus OFFICE B30/T30/
T33/ME OFFICE 70
Approx. 15 W
(ISO/IEC24712 Pattern)
Approx. 2.0 W
Approx. 0.4 W

1.4.2 Environmental Conditions

Condition
Temperature
10 to 35°C
Operating
(50 to 95°F)
Storage
-20 to 40°C*
(unpacked)
(-4°F to 104°F)
Note *1 : The combined Temperature and Humidity conditions must be within the blue-shaded
Fig.1-3
range in
*2 : No condensation
*3 : Must be less than 1 month at 40°C.
Humidity (%)
When returning the repaired printer to the customer, make sure
C A U T I O N
the Printhead is covered with the cap and the ink cartridge is
installed.
If the Printhead is not covered with the cap when the printer is
off, turn on the printer with the ink cartridge installed, make
sure the Printhead is covered with the cap, and then turn the
printer off.
General Specifications
Table 1-11. Environmental Conditions
*1
*1,2
Humidity
Shock
20 to 80%
(1 msec or less)
3
5 to 85%
(2 msec or less)
.
90
80
70
60
50
40
30
20
27/80
10/50
20/68
30/86
Temperature (°C/°F)
Figure 1-3. Temperature/Humidity Range
Revision C
Vibration
1G
0.15G,
10 to 55Hz
2G
0.50G,
10 to 55Hz
35/95
40/104
16
Confidential