Safety Components - Riello RLS 190/E Installation, Use And Maintenance Instructions

Dual fuel light oil/gas burners
Table of Contents

Advertisement

Flame inspection window
Clean the flame inspection window 1)(Fig. 50).
D10500
Filters
Check the filtering baskets on line and at nozzle present in the sys-
tem. Clean or replace if necessary.
If rust or other impurities are observed inside the pump, use a sep-
arate pump to lift any water and other impurities that may have de-
posited on the bottom of the tank.
Nozzles
It is advisable to replace nozzles every year during regular main-
tenance operations.
Do not clean the nozzle openings; do not even open them.
Flexible hoses
Check to make sure that the flexible hoses are still in good condi-
tion and that they are not crushed or otherwise deformed.
Gas leaks
Make sure that there are no gas leaks on the pipework between the
gas meter and the burner.
Gas filter
Change the gas filter when it is dirty.
Flame sensor
In order to reach the flame sensor, proceed as follows:
 extract the sensor 2);
 clean the glass cover from any dust that may have accumu-
lated.
2
20095074
Maintenance
Burner
Check for excess wear or loose screws. Also make sure that the
screws securing the electrical leads in the burner connections are
fully tightened.
Clean the outside of the burner.
1
Combustion
Adjust the burner if the combustion values found at the beginning
of the operation do not comply with the regulations in force, or at
any rate, do not correspond to good combustion.
6.2.4
The safety components must be replaced at the end of their life
cycle indicated in Tab. M. The specified life cycles do not refer to
the warranty terms indicated in the delivery or payment conditions.
Fig. 50
Safety component
Flame control
Flame sensor
Gas valves (solenoid)
Pressure switches
Pressure adjuster
Servomotor (electronic
cam) (if present)
Oil valve (solenoid)
(if present)
Oil regulator (if present)
Oil pipes/ couplings
(metallic) (if present)
Flexible hoses (if present)
Fan impeller
20086820
Fig. 51
38
GB

Safety components

10 years or 250,000
10 years or 250,000
10 years or 250,000
10 years or 250,000
10 years or 250,000
10 years or 250,000
10 years or 250,000
5 years or 30,000 pressurised
10 years or 500,000 start-ups
Life cycle
operation cycles
operation cycles
operation cycles
operation cycles
15 years
operation cycles
operation cycles
operation cycles
10 years
cycles
Tab. M