1
MOUNTING & WIRING
MOUNTING
Using the provided mounting template, mount the sensor, ensuring that the bottom of the sensor is
within 2 inches of the bottom of the door header.
Refer to Application Note 76.0035 if an IXIO Spacer is required for the given application.
Route the harness (20.5349) using the harness clip as shown in the exploded view of the mounting
illustration.
Harness shall be routed separated from any Mains or non-Class 2 voltage cable for correct operation or shall be rated for the Mains
voltage, and suitable protection and routing means shall be used according to National and Local Codes to prevent damage to the
WIRING
RED
BLACK
BROWN
BLUE
WHITE (COM)
YELLOW (N.C)
GREEN (N.O.)
PURPLE
PURPLE
* The sensor LED will briefly flash RED during monitoring communication with door control, indicating that
external monitoring is functional. Monitoring functionality must be active on the sensor, door control, and
monitoring wires must be properly connected to the door control.
75.5751.12 IXIO-DT1 20230913
Sensor connectivity (power and relays) must utilize only the supplied harness.
Sensor power must be supplied from a Class 2 supply source limited to 15 W.
Sensor is intended to be monitored for proper operation by the door operator or system.
POWER SUPPLY
POWER SUPPLY
SAFETY INPUT
SAFETY INPUT
OPENING INPUT
OPENING INPUT
OPENING INPUT
TEST OUTPUT*
TEST OUTPUT*
Mounting is compatible with the WIZARD.
harness and/or IXIO sensor.
VOLTAGE
Power:
12 – 24 VAC, 50/60 Hz
12 – 30 VDC
2.5 W (max)
Test:
low: < 1 V
high: > 10 V (30 V max.)
response time: typ. < 5 ms
Page 5 of 12