MOUNTING & WIRING
TIP!
Mounting and wiring are compatible with the Wizard.
** SEE APPLICATION NOTES OR CONTACT BEA FOR TECHNICAL SUPPORT
Harness shall be routed separated from any Mains or non-Class 2 voltage cable for correct operation or shall be rated for the Mains voltage,
and suitable protection and routing means shall be used according to National and Local Codes to prevent damage to the harness.
2

SAFETY ZONE

OR
PUSH
2X
Activate the visible spots.*
The arrow position determines the width of the detection field.
Mounting
height
6.6 ft
7.2 ft
8.2 ft
9.8 ft
11.5 ft
Page 2 of 8
Sensor connectivity (power and relays) must utilize only the supplied harness.
Sensor power must be supplied from a Class 2 supply source limited to 15 W.
Sensor is intended to be monitored for proper operation by the door operator or system.
CLOSER
AWAY
If necessary, adjust the AIR-curtain
angle (from -7° to 4°, default 0°).
Detection
width
6.6 ft
7.2 ft
8.2 ft
9.8 ft
11.5 ft
12-24 V AC, 50/60 Hz
12-35 V DC
Max 2.5 W
*
* Output status when sensor is operational
** The distance between the inner curtain of the inside door sensor and the inner
curtain of the outside door sensor should always be smaller than 8 inches.
Always verify the actual detection field width
with this user's guide and not the Spotfinder,
which detects the whole emitted field.
The size of the detection field varies according to the mounting height of the sensor.
75.5785.01 IXIO-ST UL INDUSTRIAL 20140402
RED
SUPPLY VOLTAGE
BLACK
WHITE
NOT USED
GREEN
BROWN
BLUE
SAFETY INPUT
PURPLE
TEST
YELLOW
OUTPUT **
max.
3.5 in**
* Visibility depends on external conditions
TIP!
Always
remember to
also adjust the
width via the
LCD or remote
control
(see p. 5)
The full door width must be covered.