Current Consumption –
NOTEE: Power Dissipation minimally varies between 100 and 240 V~. This data is based on all operating voltages
(100 - 240 V~).
ModelE: DPA 2K4Q / DPA 2K4Q
Output Level
Load
Standby
Mute All
Idle
8 Ω / Channel
1/8 Rated
Power (Pink
4 Ω / Channel
Noise)
2 Ω / Channel
8 Ω / Channel
1/3 Rated
Power (1kHz
4 Ω / Channel
Sine Wave)
2 Ω / Channel
ModelE: DPA 4K4Q / DPA 4K4Q
Output Level
Load
Standby
Mute All
Idle
8 Ω / Channel
1/8 Rated
Power (Pink
4 Ω / Channel
Noise)
2 Ω / Channel
8 Ω / Channel
1/3 Rated
Power (1kHz
4 Ω / Channel
Sine Wave)
2 Ω / Channel
TD-001585-01-B
All manuals and user guides at all-guides.com
n
120 V~ Mains
100 V~
AC Current
Current
(Amps)
0.5
0.5
0.8
0.7
1.1
0.9
4.1
3.44
3.9
3.25
4.9
4.09
7.9
6.6
8.7
7.24
9.6
7.97
n
120 V~ Mains
100 V~
AC Current
Current
(Amps)
0.6
0.5
0.8
0.7
1.1
0.9
5.3
4.4
5.6
4.7
6.1
5.1
11.1
9.3
11.7
9.7
12.8
10.7
22
230 V~ Mains
Losses
AC Current
Losses
(Watts)
(Amps)
(Watts)
44
0.4
31
0.5
101
0.6
180
1.98
158
1.97
247
2.27
252
3.44
316
3.75
405
4.11
230 V~ Mains
Losses
AC Current
Losses
(Watts)
(Amps)
(Watts)
45
0.4
32
0.5
102
0.6
199
2.4
231
2.5
288
2.7
291
4.8
350
5
473
5.5
Thermal Dissipation
BTU/h
kcal/h
40
150
35
106
98
345
170
614
155
193
539
136
247
843
212
233
860
217
293
1079
272
379
1382
348
Thermal Dissipation
BTU/h
kcal/hr
45
154
36
109
100
348
191
679
171
220
788
199
258
983
248
261
993
250
320
1195
301
443
1614
407
38
27
87
39
28
88