PDV Series
Venting Specifications for:
RG2PDV(40,50)S
Terminating
Through the Wall
Through the Wall
Through the Wall
Through the Wall
Through the Roof
Through the Roof
Through the Roof
Through the Roof
Through the Wall
Through the Wall
Through the Wall
Through the Wall
Through the Wall
Through the Roof
Through the Roof
Through the Roof
Through the Roof
Through the Roof
Vent Tables
2" Diameter (5.1 cm) Vent Connector Lengths
# of
Elbows
1
2
3
4
0
1
2
3
3" Diameter (7.6 cm) Vent Connector Lengths
# of
Terminating
Elbows
1
2
3
4
5
0
1
2
3
4
Maximum Straight
Minimum Straight
Length ft. (m)
Length ft. (m)
30 (9.1)
25 (7.6)
20 (6.1)
15 (4.6)
35 (10.7)
30 (9.1)
25 (7.6)
20 (6.1)
Maximum
Straight
Length ft. (m)
Length ft. (m)
80 (24.4)
75 (22.9)
70 (21.3)
65 (19.8)
60 (18.3)
85 (25.9)
80 (24.4)
75 (22.9)
70 (21.3)
65 (19.8)
2 (.6)
2 (.6)
2 (.6)
2 (.6)
7 (2.1)
7 (2.1)
7 (2.1)
7 (2.1)
Minimum
Straight
10 (3.1)
10 (3.1)
10 (3.1)
10 (3.1)
10 (3.1)
15 (4.6)
15 (4.6)
15 (4.6)
15 (4.6)
15 (4.6)
7
7
7