Bradford White LG2PDV50H60N Service Manual page 21

Power direct vent gas water heaters
Hide thumbs Also See for LG2PDV50H60N:
Table of Contents

Advertisement

PDV Series
Blower Removal
Step 1. Position gas control power switch to
"OFF" position and adjust control to call
for heat.
Step 2.
Unplug blower power cord from wall
outlet.
Step 3.
Disconnect vent system from exhaust
adapter on top of blower.
Step 4.
Remove exhaust adapter from blower
(blade screw driver) and retain for use
on new blower.
Step 5.
Unplug cord sets from blower.
Step 6.
Remove vertical air intake bracket.
Step 7.
Disconnect vertical air intake from
blower.
Step 8.
Remove the three blower mounting
screws (1/4" nut driver).
Step 9.
Remove blower with gasket from
water heater.
Blower Installation
Step 10. Clean any debris from jacket head
of water heater.
Step 11.
Set new blower with gasket in
place using locating pins on
blower flange to line up with
location holes in jacket head. Be
sure not to damage gasket.
Step 12.
Secure blower in place using
mounting screws from step 8.
Step 13.
Re-install exhaust adapter from
step 4.
Step 14.
Reconnect vent system to exhaust
adapter.
Step 15.
Reconnect cord sets from step 5.
Step 16.
Plug blower power cord into wall
outlet.
Step 17.
Position gas control power switch
to the "ON" position.
Step 18.
Verify proper blower operation.