Bradford White LG2PDV50H60N Service Manual page 10

Power direct vent gas water heaters
Hide thumbs Also See for LG2PDV50H60N:
Table of Contents

Advertisement

PDV Series
Power Up Sequence
1. Start Up.
Upon Power up, the control runs a safe-start check with a typical start-up delay of
1-5 seconds.
2.
Flammable Vapor.
To assure no outputs are energized if the "Flammable Vapor Sensor" is out of
range, the control will test the "Flammable Vapor Sensor" or for proper operating
range. If the "Flammable Vapor Sensor" is out of range, the control LED
immediately flashes 7 times with 3 second pause.
Normal Heating Sequence
1.
Thermostat calls for heat.
Prior to energizing blower, gas control checks safety circuit to insure the circuit is
open. Normal switch positions in the safety circuit are as follows:
a) Exhaust pressure switch normally open.
b) Blower temperature switch normally closed.
If the safety circuit is closed, the control waits 4 seconds, gas control LED
flashes 2 times with 3 second pause. Gas control waits 2 minutes then,
blower runs for 30 seconds. This cycle repeats until safety circuit opens.
2.
Blower energizes.
3.
Blower pre-purge period (15 seconds)
4.
Differential pressure switch proves blower/vent system operation.
If the pressure switch does not close within 30 seconds, the control LED flashes 3
times with 3 second pause. The blower runs for 30 seconds every 2 minutes trying
to get the pressure switch or blower temperature switch to close. This cycle repeats
as long as there is a call for heat.
5.
Trial for pilot ignition (90 seconds).
a. The gas control lights the pilot by activating spark igniter and gas flow to pilot
burner.
b. If flame is not sensed within 90 seconds, igniter and gas flow are
deactivated, blower will post purge and control LED flashes 6 times with 3
second pause.
6.
Main burner ignition.
After pilot flame is sensed, gas control activates main valve for main burner ignition.
The gas control will ignore flame and pressure switch signals for 3 seconds allowing
for main burner to stabilize.