PDV Series
Power supply
Dedicated 115 VAC, 60 Hz, 15A.
Minimum 1/2" NPT (schedule 40 black iron pipe recommended).
Gas Supply Pipe
Approved Gas
Natural Gas or Propane, unit must match gas type supplied.
Type
5.0" W.C. min. for Natural Gas, 11.0" W.C. min. for Propane, 14.0" W.C. maximum
Gas Pressure
(Natural Gas & Propane).
Venting System
Power direct vent through the wall or vertical through the roof.
Approved Vent
PVC, CPVC or ABS.
Materials
Minimum
18" from top, 24" from front, 4" sides and rear.
Clearance for
Servicing
Water Supply
150 PSI maximum allowable working pressure. Check local codes for supply
Pressure
pressure.
Gas Control
Residential 188°F (87°C), Commercial 199°F (93°C).
ECO Limit
Residential
60°F (16°C) to 160°F (71°C) (approximate temperatures).
Temperature Set
Point Range
Commercial
80°F (27°C) to 180°F (82°C) (approximate temperatures).
Temperature Set
Point Range
Blower
Normally closed, opens @ 155°F (68°C), auto reset @ 135°F (57°C).
Temperature
Switch
Normally open, closes on vacuum increase @ -.80" W.C.;
Pressure Switch
Opens on vacuum decrease @ -.73" W.C.
115 VAC, 60 Hz, 3.1 amps, 3000 RPM.
Blower