Installation Manual
00825-0100-5710
3
Wiring the channels
3.1
Available channels
Signal
Channel A
Wiring
1
terminals
mA Inputs
mA Output 1 (HART)
and Outputs
Frequency
Frequency Output 2
Outputs
Discrete
Discrete Output 2
Outputs
Discrete
Inputs
3.2
Access the wiring channels
Procedure
1. Remove the wiring access cover to reveal the I/O wiring terminal block connectors.
2. Confirm which transmitter channels are activated, or ON, and identify the type of
Installation Manual
Channel B
2
3
mA Output 2
Frequency Output 1
Discrete Output 1
Discrete Input 1
Figure 3-1: Channels on the Transmitter Terminal
configuration you will be wiring to based on the options available.
Channel C
4
5
RS-485
Wiring the channels
October 2023
6
23