Specifications - Bradford White PDX Series Service Manual

Powered direct vent gas water heaters
Table of Contents

Advertisement

PDX Series
Power supply
Gas Supply Pipe
Approved Gas Type
Gas Pressure
Venting System
Approved Vent Materials
Minimum Clearance
for Servicing
Water Supply Pressure
Thermal well TCO Limit
Residential Temperature
Set Point Range
Commercial Temperature
Set Point Range
Blower Temperature Switch Normally closed, opens @ 155°F (68°C), auto reset @ 128°F (54°C).
Pressure switch
Blower
6
Dedicated 115VAC, 60 Hz, 15A
Minimum 1/2" NPT (schedule 40 black iron pipe recommended)
Natural or Propane. Unit must match gas type supplied.
5.0" W.C. min. for Nat gas, 11.0" W.C. min. for L.P. gas, 14.0" W.C. maximum (Nat. & L.P.)
Power direct vent through the wall or vertical through the roof
PVC, CPVC or ABS
18" from top, 24" from front, 4" sides and rear.
150 PSI maximum allowable working pressure. Check local codes for supply pressure
Residential 188°F (87°C), Commercial 199°F (93°C)
60°F (16°C) to 160°F (71°C) (Approximate temperatures)
80°F (27°C) to 180°F (82°C) (Approximate temperatures)
Standard Altitude-Normally open, closes at differential pressure of -.80.
High Altitude-Normally open, closes at differential pressure of -.73.
115VAC, 60Hz, 3.1 amps.