Burner Cleaning
Step 1.
Position gas control power switch to the "OFF" position and unplug heater from wall
outlet.
Step 2.
Turn off gas supply to water heater.
Step 3.
Remove outer jacket door and inner door per service procedure XIII on page 35.
Step 4.
Disconnect pilot tube (7/16 wrench) and
feedline (¾ wrench) from gas control.
Step 5.
Disconnect igniter/flame sensor wire from gas control.
Step 6.
Remove burner assembly from combustion chamber.
Step 7.
Thoroughly inspect burner surface area and burner port area and
remove any loose debris.
Step 8.
For cast iron burners, inspect for any debris build up inside
burner casting.
Step 9.
Unscrew burner from main burner
orifice. On cast iron burners, loosen
air shutter nut and unscrew feedline
from burner.
Step 10.
Remove main burner orifice from
feedline (½" wrench on steel
burners, 3/8" wrench on cast iron)
inspect orifice, clean or replace if
necessary.
Step 11.
Reassemble burner and reinstall into water heater. Restore gas supply
and check for gas leaks.
Step 12
To resume operation follow the instruction located on the lighting
instruction label or the lighting instruction located in the installation
and operating manual.
16
PDX SERVICE PROCEDURE I
Burner Operation Inspection,
Adjustment, Cleaning and Replacement
Igniter/flame
sense wire
Burner
surface area
Burner
port area
Main burner
Feedline nut
Pilot tubing nut
orifice
L.P. Main burner
orifice. Left hand
thread
Page 16

Advertisement

Table of Contents
loading

Table of Contents