Bradford White PDX Series Service Manual page 19

Powered direct vent gas water heaters
Table of Contents

Advertisement

PDX Series
Exhaust Pressure Switch
Replacement
Step 1.
Position gas control power switch
to "OFF" position.
Step 2.
Remove the three screws (Phillips screw driver) from control access cover on blower assembly and
remove cover (see photo 3).
Step 3.
Carefully remove pressure
switch from blower
housing (see photo 4)
Step 4.
Disconnect tubing from
pressure switch.
(see photo 5)
Step 5.
Disconnect yellow wires
from pressure switch
(see photo 6)
Step 6.
Reconnect wires from step 5 to new pressure switch.
Step 7.
Reconnect tubing to new pressure switch.
Step 8.
Carefully position pressure switch into blower housing.
Step 9.
Position gas control power switch to "ON" position and verify proper heater operation.
Step 10.
Replace control access cover from step 2.
120 volt potential exposure. Use caution
4
PDX SERVICE PROCEDURE III
Pressure Switch Testing and
Replacement
WARNING
to avoid personal injury.
5
Slide pressure switch in direction of
arrow while tilting slightly away
from blower housing.
6
Pressure Switch
7
Page 19
19