Bradford White Defender Safety System 238-48248-00 Instruction Manual Supplement

Bradford White Defender Safety System 238-48248-00 Instruction Manual Supplement

Programmable flammable vapor ignition resistant gas water heater

Advertisement

SUPPLEMENT TO INSTRUCTION MANUAL
You have just purchased one of the finest water heaters on the market today!
This installation, operation and instruction manual will explain in detail the installation
and maintenance of your new Programmable Flammable Vapor Ignition Resistant Gas
Water Heater. We strongly recommend that you contact a plumbing professional for
the installation of this water heater.
We require that you carefully read this manual, as well as the enclosed warranty, and
refer to it when questions arise. If you have any specific questions concerning your
warranty, please consult the plumbing professional from whom your water heater was
purchased. For your records, we recommend that you write the model, serial number
and installation date of your water heater in the maintenance section in the back of this
manual.
Special Flammable Vapor Ignition Resistant System:
This water heater is equipped with a Flammable Vapor Ignition Resistant System. In
the event of improper usage or storage of gasoline or other flammable materials in the
location where the water heater is installed, the technology will resist ignition of the
flammable vapors outside the confines of the water heater.
The Flammable Vapor Ignition Resistant System Features:
Advanced Flame Arrestor Design
Re-settable Thermal Switch to prevent burner/pilot operation with restricted
airflow
Flammable Vapor Sensor
Automatic Ignition Device
Sight Window to observe operation of pilot and burner
FOR YOUR SAFETY: Activation of the Flammable Vapor Ignition Resistant System
occurs when flammable vapors are drawn into the water heater and are combusted. If
flammable vapors are detected:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Leave the premises and immediately call the fire department from a
neighbor's phone. Follow the fire department's instructions.
Once the flammable vapor has been evacuated, contact your plumbing professional or
the manufacturer for further instructions. Replacement of a Flammable Vapor Ignition
Resistant System equipped water heater due to a flammable vapor shutdown is not
covered under the terms of the limited warranty.
PE MODEL WATER HEATERS
P/N 238-44219-00
(Replaces pg. 2 in instruction manual.)
CONGRATULATIONS!
238-48248-00A 10/09

Advertisement

Table of Contents
loading

Summary of Contents for Bradford White Defender Safety System 238-48248-00

  • Page 1 For your records, we recommend that you write the model, serial number and installation date of your water heater in the maintenance section in the back of this manual.
  • Page 2: Minimum Clearances

    If it is necessary to install this water heater in an alcove, use the clearances listed in Figure 1.
  • Page 3: Lighting And Shutdown Instructions

    Lighting and Shutdown Instructions (Replaces pg. 18 in instruction manual.) FOR YOUR SAFETY READ BEFORE WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition device which automatically lights the pilot.
  • Page 4: Thermostat Adjustment

    Note: Whenever the water heater is filled with cold water, condensate will form on the cool tank surface and drops of water will fall on the hot burner and combustion chamber surfaces producing a “sizzling”...
  • Page 5: Burner Flame Check

    BURNER FLAME CHECK (Replaces pg. 22 in instruction manual.) Steel Burner: These models are equipped with self adjusting air mixture and do not have an adjustable air shutter (See Figure 3). At periodic intervals, a visual check of the main burner and pilot flames should be made to determine if they are burning properly.
  • Page 6: Installation For Potable Water

    INSTALLATION FOR POTABLE WATER (Replaces pg. 28 in instruction manual.) Figure 4...
  • Page 7: Parts List Drawing

    (Replaces pg. 29 in instruction manual.) PARTS LIST DRAWING Figure 5...
  • Page 8: Parts List

    (Replaces pg. 30 in instruction manual.) 1. Draft hood 2. Setback Control Junction Box Assembly 3. Jacket head 4. Jacket 5. Heat trap (outlet) 6. Anode Outlet Device 7. Heat trap (inlet) 8. Baffle 9. Diptube 10. T&P valve 11. Tank 12.
  • Page 9 Toxic chemicals, such as those used for boiler treatment, must not be introduced into potable water used for space heating. This water heater must not be connected to an existing heating system or component(s) previously used with a non-potable water heating appliance.
  • Page 10 This water heater is equipped with a flammable vapor sensor. If the sensor is exposed to flammable vapor, the water heater control will shut down the water heater and display a code of 7 flashes and then a 3 second pause.
  • Page 11: Electrical Connections

    If a flexible line cord and plug is permitted by local code, then provide a (3) three wire grounding type receptacle within 6 ft (1.9 m) of the water heater and use the flexible cord provided. Do not plug the line cord into a receptacle that can have its power supply interrupted by a switch that is used to turn on and off lights.
  • Page 12: Wiring Diagram

    (In addition to the instruction manual.) PILO POWER SETBACK JUNCTION TRANSFORME IF ANY OF THE ORIGINAL WIRES SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WITH APPLIANCE WIRE MATERIAL WITH A MINIMUM TEMPERATURE RATING OF 105°C AND A MINIMUM SIZE OF NO. 18 AWG. Wiring Diagram Honeywell PLUG-IN...
  • Page 13: Troubleshooting

    (In addition to instruction manual.) LED Status None (LED not on Electrical pow er not or flashing) One short flash every four Thermostat is satisfied (no seconds Alternates bright Thermostat calling for heat and dim (heartbeat) Short flash once Weak pilot signal on last every second Tw o flashes, three second...
  • Page 14 Troubleshooting continued- LED Status Six flashes, tw o Relay not w orking properly flashes, three during burner operation, second pause system auto resets after (Soft Lockout) Six flashes, three Pilot flame extinguished, flashes, three system auto resets after second pause (Soft Lockout) Six flashes, four Undesired false pilot flame...
  • Page 15 The main burner continues to operate until the thermostat is satisfied. When the thermostat is satisfied, the main and pilot gas valves close. The relay contacts remain closed for a short period before opening. The water heater remains in the stand-by mode until the next call for heat.
  • Page 16 Notes...

Table of Contents