System Details; Water; Water Quality; Water Flow - Cornelius 2 Flavor Training Manual

Quest juice 2 and 4 flavor
Table of Contents

Advertisement

W
ATER

Water Quality

Water quality has an affect on juice dispensing systems.
odor
taste
clarity/foaming
Water filtration is recommended to assure the best beverage taste.

Water Flow

Inlet water pressure should be regulated to 45 to 50 psi max. (3.1 bar) to prevent damage to pump tub-
ing. Minimum flowing pressure must be 20psi.
Flow Rates
Adequate water flow is necessary and must be at least 3.0 ounces per second (89ml) at the inlet to the
unit.
C
ONCENTRATE
Concentrate should be stored frozen and put into a cooler 72 hours before use. Rapid cooling, such
as in a sink of hot water, adversely affects flavor and leads to service calls.
Proper loading of concentrate is important. Improper loading is a major source of service calls.
Left and Right Pump Platforms
Concentrates vary in viscosity and mixing valves must be adjusted accordingly.
When changing concentrate, be sure to check the concentrate container O-ring for damage. It should
be clean and wet with concentrate or a food grade lubricant.
Shake or stir pulp based concentrates.
When changing flavors, be sure to flush the system and reset the pump.
Nozzles should be cleaned daily. Remove the nozzles and wash in warm soap solution. Rinse with
clean water, lubricate the O-ring, and replace nozzle.
Flushing daily and sanitizing weekly is recommended.
S
B
ETTING THE
RIX
A refractometer must be used to measure the post-mix brix.
Ratio adjustment can be set with a concentrate separator and ratio cup, see Brixing Procedure.
Ratios are sometimes set by taste but this is not recommended.
© 2004, IMI Cornelius Inc.

SYSTEM DETAILS

Cabinet
Cooling Fan
- 3 -
Quest Juice Training Manual
Serial Decal
Lighted Merchandiser
ON/OFF
Platform Pump
ON/OFF
Publication Number: TP00968

Advertisement

Table of Contents
loading

This manual is also suitable for:

4 flavor

Table of Contents