System Configuration - Omron CP2E Manual

Micro plc designed to support data collection and machine to machine communication
Table of Contents

Advertisement

Accessories (Order Separately)
Name
Specifications
Memory Cassette EEPROM (for data
security and copying)
Connecting Cable 2 m RS-232C (9-pin D-
sub connector)
USB-Serial
0.5m USB (type A plug,
Conversion Cable
male), RS-232C (D-sub
9-pin, male)
Battery Unit
10 years min. Battery life
(at 25°C)
ZEN Support
Runs on Windows 95, 98,
Software
2000, Me, XP, NT4.0
Service Pack3, Vista
(32bit), Windows7 (32-
bit/64-bit version),
Windows10 (32-bit/64-bit
version)
Note: 1. Memory Cassettes created using a CPU Unit can be read to other CPU Units, regardless of which model is used. Restrictions, apply, however,
to the functions that can be used, depending on the CPU Unit version combination. For details, refer to Memory Cassette and CPU Unit
Combinations on page 31.
2. Standard LCD-type, Economy-type, and Communications-type CPU Units (i.e., excluding ZEN-@C2@@-@-V2 models).
3. LED-type CPU Unit without display (i.e., ZEN-@C2@@-@-V2 models).
Mounting Accessories (Order Separately)
Name
Specifications
Mounting Track
50 cm (l) × 7.3 mm (t)
1 m (l) × 7.3 mm (t)
1 m (l) × 16 mm (t)
End Plate
Spacer

System Configuration

Power Supply Unit
Note: 1. Up to 3 Expansion I/O Units can be connected to any type of CPU Unit except for Economy-type CPU Units. Expansion I/O Units with AC Inputs,
however, cannot be connected to CPU Units with DC Power Supplies.
2. The Connecting Cable and Memory Cassette cannot be connected to the ZEN at the same time.
3. Programs cannot be written to LED-type CPU Units (i.e., ZEN-@C2@@-@-V2 models) without the ZEN Support Software or a Memory Cassette.
Enables programs and parameter settings to be saved or copied to another
ZEN. (See note 1.)
Transfer from ZEN to
Memory
Transfer from Memory
Cassette to ZEN
Memory Cassette
initialization
For notebook computers that do not have an RS-232C serialport, connect the
computer to the ZEN by connecting an OMRON CS1W-CIF31 USB-Serial
Conversion Cable to the ZEN-CIF01 Connecting Cable.
Attached drivers (On CD-ROM)
Ladder programs and parameter settings are saved to the CPU Unit EEP-ROM
but calendar, clock, and holding timer bits and holding timer/counter present
values are held by the capacitor. Therefore, if the power supply is interrupted
for 2 days or more (at 25°C), this data will be reset. Use a Battery Unit for
systems where the power supply may be interrupted for long periods.
Specifically designed for the ZEN (CD-ROM).
Model
PFP-50N
PFP-100N
PFP-100N2
PFP-M
PFP-S
CPU Unit
Battery Unit
Connecting Cable
Memory Cassette
Remarks
LCD-type CPU Unit with
LED-type CPU Unit without
display (See note 2.)
display (See note 3.)
Supported
Not supported
Supported
Automatic transfer when
power turned ON
Supported
Not supported
Expansion I/O Units
Support Software
ZEN V2 Units
Model
ZEN-ME01
ZEN-CIF01
CS1W-CIF31
ZEN-BAT01
ZEN-SOFT01-V4
6

Advertisement

Table of Contents
loading

Table of Contents