Lenovo 7Z59 Manual page 161

Hide thumbs Also See for 7Z59:
Table of Contents

Advertisement

User Action:
Complete the following steps:
1. Reseat the affected DIMM (Note: The event Log might contain a recent FQXSFMA0011I event
denoting detected change in DIMM population that could be related to this problem.)
2. Boot to F1 setup and re-enable the DIMM. Reboot the system.
3. Update UEFI firmware to the latest version.
4. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFMA0029I: The PFA of DIMM [arg1] has been deasserted after applying PPR for this DIMM.
[arg2]
Severity: Info
User Action:
Information only; no action is required.
• FQXSFMA0030K: Intel Optane PMEM [arg1] Percentage Remaining is less than [arg2]% and still
functioning.
Severity: Warning
User Action:
Complete the following steps:
1. Check the current Intel Optane PMEM DIMM health status in one of the following ways:
a. Run PMEM test under LXPM diagnostic. Look for "Percentage Remaining" of spare blocks.
b. Check for "Remaining Life" of spare blocks on the XCC Web GUI.
2. Back up data.
• FQXSFMA0031K: Intel Optane PMEM [arg1] has reached 1% remaining spares block and still
functioning.
Severity: Warning
User Action:
Complete the following steps:
1. Check the current Intel Optane PMEM DIMM health status in one of the following ways:
a. Run PMEM test under LXPM diagnostic. Look for "Percentage Remaining" of spare blocks.
b. Check for "Remaining Life" of spare blocks on the XCC Web GUI.
2. Back up data.
3. Check if the PMEM meets warranty terms.
a. If the PMEM meets the warranty terms, contact Lenovo Support for PMEM replacement.
b. If the PMEM does not meet the warranty terms, order a new comparable PMEM through an
authorized Lenovo reseller.
4. Collect Service log and contact Lenovo support to schedule PMEM replacement.(Note: Unless
otherwise specified in other agreements or contract terms, parts beyond their warranty terms and/or
parts that have reached their maximum usage limitations do not qualify for warranty service.)
• FQXSFMA0032M: Intel Optane PMEM [arg1] has no remaining spares block.
Severity: Error
User Action:
.
157