Lenovo 7Z59 Manual page 131

Hide thumbs Also See for 7Z59:
Table of Contents

Advertisement

CIM Prefix: PLAT CIM ID: 0518
User Action:
Information only; no action is required
• FQXSPUN0018J: Sensor [SensorElementName] has transitioned from normal to non-critical state.
This message is for the use case when an implementation has detected a Sensor transitioned to non-
critical from normal.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - Other
SNMP Trap ID: 60
CIM Prefix: PLAT CIM ID: 0520
User Action:
Please check event log of XClarity Controller to investigate the identified device for enhancement.
• FQXSPUN0019M: Sensor [SensorElementName] has transitioned to critical from a less severe
state.
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0522
User Action:
Complete the following steps:
1. Please check XCC web GUI to see the identified error.
2. Check system event log to fix the error.
3. If the problem still exist, please contact local service.
• FQXSPUN0023N: Sensor [SensorElementName] has transitioned to non-recoverable.
This message is for the use case when an implementation has detected a Sensor transitioned to non-
recoverable.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0530
User Action:
Complete the following steps:
1. Check the Lenovo support site for an applicable service bulletin or firmware update that applies to
this error.
2. Reboot the system.
.
Chapter 2
XClarity Controller events
127

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thinksystem sr860 v27z60

Table of Contents