Programming ''Wake Up'' (Wake Up Time) Into Unit; Programming Point Of Sale Message Display; Table 6. Motor Select; Table 7. Point Of Sale Display Messages - Cornelius R-404A REFRIGERANT Service Manual

Fcb overcounter post-mix dispenser with v3+features (r-404a refrigerant)
Hide thumbs Also See for R-404A REFRIGERANT:
Table of Contents

Advertisement

DISPLAYED
MODEL
KLBER
60
Klauber
FASV3 60
Fasco/VW
FASCWR 60
Fasco/VW
VW/GE 60
Fasco/VW
EMRSN 60
Emerson
BODINE 60
Bodine
KLBER
50
Klauber
FASV3
Fasco/VW
FASCWR 50
Fasco/VW
VW/GE 50
Fasco/VW
EMRSN 50
Emerson
DIP SWITCH
DIP SWITCH
NO. 1
NO. 2
OFF
OFF
OFF
ON
ON
OFF
ON
ON
*For special messages, contact your local sales representative.

PROGRAMMING ''WAKE UP'' (WAKE UP TIME) INTO UNIT

''WAKE UP'' (WAKE UP TIME) may be programmed into Unit to occur any time of the day to wake Unit up (return
to normal operation) after ''sleep time'' has occurred. Program ''WAKE UP'' into Unit as follows:
1. Refer to PROGRAMMING MAIN MENU SELECTIONS ONTO MESSAGE DISPLAY and bring up ''WAKE
UP'' on message display. Press ''DEFROST'' (SELECT) switch to lock in on selection.
2. Press ''CANCEL DEFROST'' (ADVANCE) switch to bring up flashing hour number on display.
3. Press ''CANCEL DEFROST'' (ADVANCE) switch to advance hours on display to desired hour. Press ''DE-
FROST'' (SELECT) switch to lock in hour on display.
4. After hour (time of day) has been locked in on message display, minute numbers will be flashing on display.
Press ''CANCEL DEFROST'' (ADVANCE) switch to advance minute numbers to desired minutes (time of
day). Press ''DEFROST'' (SELECT) switch to lock in minutes (time of day) on display.
5. Press ''ERROR RESET'' switch two times to exit from MENU SELECTIONS.

PROGRAMMING POINT OF SALE MESSAGE DISPLAY

(see Figure 4 and 7)
NOTE: Point of sale display messages may be turned off by placing No. 1 DIP SWITCH on master circuit
board in "OFF" position and No. 2 DIP SWITCH in "ON" position (see Figure 4 and 5 and 7).
HZ
60
Over/under gear box with a GE wide-range voltage motor.
60
Over/under gear box with a Fasco wide-range voltage motor.
60
Standard gear box using a Fasco wide-range voltage motor.
60
Standard gear box with a GE 219/242 volt motor.
60
Over/under gear box with an Emerson wide-range motor.
60
Special wide-range motor.
50
Over/under gear box with a GE wide-range voltage motor.
50
Over/under gear box with a Fasco wide-range voltage motor.
50
Standard gear box using a Fasco wide-range voltage motor.
50
Standard gear box with a GE 219/242 volt motor.
50
Over/under gear box with an Emerson wide-range motor.

TABLE 6. MOTOR SELECT

"ENJOY A FROZEN BEVERAGE"
NOT USED - BLANK
"HAVE A NICE DAY"
"DISFRUTE UNA BEBIDA CONGELADA CARBONATADA"

TABLE 7. POINT OF SALE DISPLAY MESSAGES

MOTOR DESCRIPTION
*MESSAGE
19
312028000