Displayed Error Conditions - Cornelius R-404A REFRIGERANT Service Manual

Fcb overcounter post-mix dispenser with v3+features (r-404a refrigerant)
Hide thumbs Also See for R-404A REFRIGERANT:
Table of Contents

Advertisement

1. Refer to PROGRAMMING MAIN MENU SELECTIONS ONTO MESSAGE DISPLAY and bring up "REF
TYPE" (REFRIGERANT TYPE) on the message display. Press "DEFROST (SELECT) switch to lock in on
the selection. The sub menu of refrigerant types that may be brought up on the MESSAGE DISPLAY from
"REF TYPE" (REFRIGERANT TYPE) are as follows:
A.
"R404A2HP"
(V3+ Dispenser with 2 H.P. Copeland Compressor and R-404A refrigerant).
B.
"R404A3HP"
(V3+ Dispenser with 3 H.P. Copeland Compressor and R-404A refrigerant).
C.
"R502"
(V3 and V3+ Dispensers using Bristol or Tecumseh Compressor and R502 refrigerant).
D.
"R402B5OH"
(V3 and V3+ Dispensers using a Bristol Compressor and R-402B refrigerant).
2. Refer to Dispenser serial plate to identify the type of refrigerant gas installed in the refrigeration system.
3. Press "CANCEL DEFROST" (ADVANCE) switch as many times as necessary to bring up applicable refriger-
ant type from sub menu of "REF TYPE" (REFRIGERANT TYPE) on MESSAGE DISPLAY.
4. Press "DEFROST" (SELECT) switch to lock in on the selection. This programs the proper refrigerant pulse
rate into the Dispenser electronics.
5. Press "ERROR RESET" switch two times to exit from "MAIN MENU SELECTIONS".

DISPLAYED ERROR CONDITIONS

Displayed error conditions, associated errors, and items affected by the errors are found in Table 9 DISPLAYED
ERROR CONDITIONS.