Trouble
FREEZE CYLINDER DOES
NOT REFILL AT ALL TIMES
WHEN DISPENSING. (cont'd)
FROZEN PRODUCT
CONSISTENCY VARIES
EXCESSIVELY.
CYLINDER FREEZE-UP.
312028000
Probable Cause
C.
Lines restricted.
A.
Dispensed product BRIX
varying because:
Syrup and/or water flow
regulator sticking.
Primary CO
regulator
2
pressure insufficient.
B.
Cylinder freeze-up causing
ice formation in center of
cylinder and liquid product
channels around ice
formation.
NOTE: DEFROST AFFECTED FREEZE CYLINDER
AS INSTRUCTED.
A.
Dispensed product BRIX too
low.
B.
Viscosity of dispensed product
not properly adjusted.
68
Remedy
C.
Sanitize Unit as instructed.
a. Clean regulator(s).
b. Primary CO
regulator must be
2
adjusted from 80 to 100-psi.
B.
Refer to CYLINDER
FREEZE-UP.
A.
Refer to BRIX (Water-to-Syrup)
''Ratio'' too low.
B.
Adjust dispensed product
viscosity as instructed.