Components
Bake heater
Oven lamp
Test procedures
1. Refer to page 3-11 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale : R x 1)
1. Measure the resistance after cooling down
(Multiple meter scale: R x1)
4-4
Results
Normal: Approximately
17 Ω ± 10%
If not replace
NOTE: Ω Value was tested
at room temperature
(77F/25˚C)
Be careful the element is
sensitive to temperature.
Normal: Below 5 Ω.
If not replace