Components
Outer Broil heater
Bake heater
Conv. heater
Test procedures
1. Remove wire leads
2. Measure resistance after cooling down
1. Remove wire leads
2. Measure resistance after cooling down
1. Remove wire leads
2. Measure resistance after cooling down
4-4
Results
Normal : Approximately 23Ω
Abnomal : Infinite(opened)
NOTE: Ω Value was tested
at room temperature
(77F/25˚C)
Be careful the element is
sensitive to temperature.
Normal : Approximately 16.5Ω
Abnomal : Infinite(opened)
NOTE: Ω Value was tested
at room temperature
(77F/25˚C)
Be careful the element is
sensitive to temperature.
Normal : Approximately 82Ω
Abnomal : Infinite(opened)
NOTE: Ω Value was tested
at room temperature
(77F/25˚C)
Be careful the element is
sensitive to temperature.