Split system single phase type
Optimisation at switch-on and switch-off
Line no.
HC1
HC2
790
1090
791
1091
Optimum start control max
The change in temperature levels is optimised in
such a way as to reach the comfort setpoint during
changeover times.
Reduced Setpoint Increase
Line no.
HC1
HC2
800
1100
801
1101
This function is used mainly in heating installations
that do not have high supplies of power (e.g. low
energy
homes).
In
temperatures are low, adjusting the temperature
would be too long.
Mixing Valve Control
Line no.
HC1
HC2
830
1130
834
1134
Mixer valve boost
The controller adds the increase set here to the
current flow setpoint and uses the result as the
temperature setpoint for the heat generator.
58
Programming line
Optimum start control max
Optimum stop control max
Programming line
Reduced setpoint increase start
Reduced setpoint increase end
that
case,
when
Begin
increase(800)
Comfort
setpoint(710)
Reduced
setpoint(712)
Programming line
Mixer valve boost
Actuator running time
Optimum stop control max
The change in temperature levels is optimised in
such a way as to reach the comfort setpoint -1/4 °C
during changeover times.
Increasing the reduced setpoint prevents excessive
cooling of the rooms in order to shorten the
outdoor
temperature adjustment period when changing over
to the comfort setpoint.
End increase
(801)
Averaged OT
Actuator running time
For 3-position control the valve Actuator running time
can be adjusted. With a 2-position servomotor, the
adjusted travel time is inoperative.
Maintenance Document 1589-3