46
FUNCTION
nd
2
phase on
nd
2
phase off
rd
3
phase on
rd
3
phase off
Copy
Default values
Holidays heating circuit 1
Preselection
Period start (Day / Month)
Period end (Day / Month)
Operating level
Holidays heating circuit 2
Preselection
Period start (Day / Month)
Period end (Day / Month)
Operating level
Heating circuit 1
Comfort setpoint
Reduced setpoint
Frost protection setpoint
Comfort setpoint maximum
Heating curve slope
Heating curve displacement
Summer/winter heating limit
Flow temp setpoint min (for fan
convectors)
Flow temp setpoint max
Room influence
Room temp limitation
Quick setback
Optimum start control max
Optimum stop control max
Reduced setpoint increase start
Reduced setpoint increase end
Mixer valve boost
Actuator running time
Floor curing function
Floor curing setpoint manually
Floor curing day current
Floor curing day completed
Optg mode changeover
Cooling circuit 1
Operating mode
Comfort setpoint
Release
Flow temp setp at OT 25°C
Flow temp setp at OT 35°C
Cooling limit at OT
Lock time at end of heating
Summer comp start at OT
Summer comp end at OT
Summer comp setp increase
SETTING RANGE
00:00...--:--
--:--
00:00...--:--
--:--
00:00...--:--
--:--
00:00...--:--
--:--
No/yes
No
Period 1...8
Period 1
01.01...31.12
01.01...31.12
Frost protection ¦ Reduced
Frost protection
Period 1...8
Period 1
01.01...31.12
01.01...31.12
Frost protection ¦ Reduced
Frost protection
Reduced temp to
20°C
35°C
19°C
4°C to Reduced
8°C
temp
20°C...35°C
28°C
0,1...4
0,5
-4,5°C...4,5°C
0°C
8°C...30°C
18°C
8°C... 95°C
8°C
8°C... 95°C
55°C
1%...100%
50%
0.5...4°C
0.5°C
Off ¦ Down to reduced
setpoint ¦ Down to frost
Off
prot setpoint
0...360min
180 min
0...360min
30 min
-30°C...10°C
---
-30°C...10°C
-5°C
0...50°C
0
30...873s
240s
0...5
Off
0°C...95°C
25°C
0...32
0...32
Protection mode
Automatic
Off ¦ Automatic
15...40°C
24°C
24h/day ¦ Time
24h/day
program HC ¦ Time
program 5
6...35°C
20°C
6...35°C
16°C
---/8...35°C
20°C
---/8...100h
24h
20...50°C
26°C
20...50°C
35°C
---/1...10°C
4°C
Maintenance Document 1589-3