Fujitsu WATERSTAGE WS A050DD6 Series Maintenance Document page 48

Table of Contents

Advertisement

Split system single phase type
COMMAND
ACCESS
LINE
LEVEL
2884
S
2886
S
2916
S
2920
S
3692
S
3700
S
3701
S
3705
S
3720
S
3723
S
DHW storage tank (with DHW kit or with integrated DHW models)
5024
S
5030
S
5055
S
5057
S
5061
S
5093
S
5700
I
5710
I
5711
I
5715
I
5731
I
5806
I
5981
S
5983
S
5985
S
6098
S
6100
S
6120
S
6205
S
6220
S
6420
I
6421
I
6600
I
6711
U
6800
S
6802
S
6804
S
6806
S
6808
S
6810
S
6812
S
6814
S
48
FUNCTION
Release el flow at OT
Compensation heat deficit
Max setpoint HP DHW charge
With electrical utility lock
Supplementary source
With DHW charging
Release below outside temp
Release above outside temp
Overrun time
Switching integral
Locking time
Switching differential
Charging time limitation
Recooling temp
Recooling collector
Electric immersion heater release
Not used
Configuration
Pre-setting
Heating circuit 1
Cooling circuit 1
Heating circuit 2
DHW ctrl elem Q3
Type el imm heater flow
Cont type input EX1
Cont type input EX2
Cont type input EX3
Not used
Readjustm outside sensor
Frost protection plant
Reset to default parameters
Software version
Function input H33
Optg mode change HCs+DHW ¦ Optg mode changeover DHW ¦ Optg mode changeover HCs ¦
Optg mode changeover HC1 ¦ Optg mode changeover HC2 ¦ Optg mode changeover HC3 ¦
Error/alarm message ¦ Release swi pool source heat ¦ Release swi pool solar ¦ Dewpoint
monitor
Contact type H33
LPB system
Not used
Errors
Reset HP
History 1
History 2
History 3
History 4
History 5
History 6
History 7
History 8
SETTING RANGE
-30°C...30°C
2°C
Off ¦ On ¦ Only with
Off
floor curing fct
8°C... 80°C
58°C
Lock/release
Released
Locked ¦ Substitute ¦
Substitute
Complement ¦ Instantly
-50...50°C
2°C
-50...50°C
0...120min
20min
0... 500°Cmin
100°Cmin
0...120min
30min
0...20°C
7°C
10...600min
90 min
8...95°C
65°C
Summer
Off ¦ Summer ¦ Always
24h/day
DHW release
DHW release
Time program 4/DHW
1 to 12
1
On
Off ¦ On
Off
Off
4-pipe system
2-pipe system
On
Off ¦ On
No charging request ¦
Diverting valve
Charging pump ¦
Diverting valve
1 : 3-stage, 2 : 2-stage
3 : 2-stage
excluding, 3 : 2-stage
complementary, 4 :
complementary
Modulating UX
NO
NC ¦ NO
NC
NC ¦ NO
NO
NC ¦ NO
-20...20°C
0°C
-3...3°C
0°C
On/off
On
No/yes
No
0...99
--
NO
NC ¦ NO
0...16
1
No/yes
No
Date/time/code
Date/time/code
Date/time/code
Date/time/code
Date/time/code
Date/time/code
Date/time/code
Date/time/code
Maintenance Document 1589-3