DeLonghi PrimaDonna Elite ECAM656.75.MS Manual page 24

Table of Contents

Advertisement

DISPLAYED MESSAGE
TURN DIAL TO <CLEAN> POSI-
TION TO START CLEANING
CLEAN
TURN THE MILK FROTH
ADJUSTMENT DIAL TO MILK
POSITION
DESCALING NEEDED
PRESS OK TO START
(~45MIN)
REPLACE WATER SOFTENER
FILTER
PRESS OK TO START
GENERAL ALARM: REFER
TO USER MANUAL / SMART
COFFEE APP
POSSIBLE CAUSE
Milk has been delivered recently and the
tubes inside the milk container must be
cleaned (D).
The milk container has been inserted
with the froth adjustment dial (D1) in the
"CLEAN" position.
The machine must be descaled.
The water softener filter (C4) is
exhausted.
The inside of the appliance is very dirty.
The appliance needs descaling and/or the
filter (C4) must be replaced.
The tubes inside the milk container (D)
must be cleaned.
REMEDY
Turn the froth adjustment dial (D1) to CLEAN (fig.
21).
Turn the dial to the required froth position.
Press "
descale later. The descaling procedure described in
section "17. Descale" needs to be performed.
Press "
" to carry out the procedure later. Follow the
instructions in section "19. Water softener filter".
Clean the inside of the appliance thoroughly, as
described in section "16. Cleaning". If the message
is still displayed after cleaning, contact a service
centre.
The descaling procedure described in section "17.
Descale" needs to be performed and/or the filter
needs replacing or removing as described in section
"19. Water softener filter".
Turn the froth adjustment dial (D1) to CLEAN (fig.
21).
29
" to start descaling or "
" to replace or remove the filter, or "
" to

Advertisement

Table of Contents
loading

This manual is also suitable for:

Primadonna elite ecam650.75.ms

Table of Contents