SYMPTOM
Unit does not travel or
travel is not smooth.
Unit does not vibrate
or has weak vibration.
PAGE 32 — V305EK VIBRATORY ROLLER • OPERATION AND PARTS MANUAL — REV. #0 (07/20/23)
Troubleshooting - Roller
POSSIBLE PROBLEM
Damaged rubber coupling and flange?
Defective travel cable and link?
Damaged scraper or too much mud in
scraper?
Low oil level?
Damaged hydraulic pump?
Damaged drum gear reduced?
Bad drum bearings?
Defective rubber shock mounts?
Defective travel V-belt?
Defective centrifugal clutch?
Damaged or slipping V-belt?
Damaged vibration cable and linkage?
Defective clutch vibrator pulley V-belt?

TROUBLESHOOTING

SOLUTION
Replace urethane coupling and flange.
Repair or replace travel cable and link.
Replace or repair scraper.
Replenish or replace oil.
Replace hydraulic pump.
Repair.
Repair or replace.
Replace.
Replace.
Repair or replace clutch.
Replace V-belt or adjust tension.
Replace or repair vibration cable and linkage.
Replace V-belt.