16 BY-PASS VALVE

16.1 Function

The By-pass valve A in Figure 16.1 is located between the c.h.
ZDWHU ÀRZ DQG UHWXUQ DQG LWV IXQFWLRQ LV WKDW RI JXDUDQWHHLQJ D
PLQLPXP ÀRZ DFURVV WKH SULPDU\ KHDW H[FKDQJHU LI WKH FLUFXOD-
tion across the c.h. system is completely closed.
7KH %\SDVV YDOYH LV ¿WWHG RQ WKH UHDU VLGH RI WKH GLYHUWHU JURXS
Figure 16.1

16.2 Removal

Warning: isolate the boiler from the mains electrici-
ty supply before removing any covering or compo-
nent.
1 Remove all the case panels.
2 Empty the primary circuit of the boiler.
3 Remove the locking plate B and pull up the by-pass valve A
(Figure 16.2).
A
B
Figure 16.2
4 Reassemble the by-pass valve as illustrated in Figure 16.2
reversing the order of removal.
BY-PASS VALVE
A
Warning: to lubricate the O-ring gaskets exclusively
use a silicone base grease compatible to be in con-
tact with foods and approved by the local water Au-
thorities.
Attention. When reassembling the By-pass valve be sure
that it is correctly oriented by matching the reference C with
the notch D of the water group Figure 16.3
A
C
Figure 16.3
D