Biasi ActivA Plus Service Manual page 24

Wall hung, fanflue, roomsealed, high efficiency gas boiler
Table of Contents

Advertisement

Figure 9.10
6 In order to pass from a parameter to another press c.h. set
keys (A or C) at the same time until P 02 are displayed on
the display, indicating the entry in the "parameter 02" and the
value of parameter (Figure 9.11)
Figure 9.11
7 Repeat the previous steps in order to display the parameter's
setting or to switch to the following
Figure 9.12
To reset the boiler to the normal operation press the key B (Figure
9.5) for 10 second or turn off the electricity supply to the boiler.
- 24 -
MAIN ELECTRONIC CONTROL/IGNITION P.C.B.
A
C
A
C
B
Important: at the end of the setting operation it is important
WR ¿OOXSGDWH WKH WDEOH LQ WKH LQVWDOODWLRQ PDQXDO VHH FKDSWHU
COMMISSIONING section: Setting record.
PARAMETER
Boiler type (to be up-
dated with the complete
range)
Type of water sensors
&K  GKZ
Pump speed
Zone valve setting
5RRP 7KHUPRVWDW 
Remote Control
Gas type
Not used
&K ÀRZ PD[
temperature °C
Factory parameters
reset
LCD
VALUES (SET)
P 01
00 = No power Er 99
35 = Activ A Plus 25C
36 = Activ A Plus 30C
37 = Activ A Plus 35C
40 = Activ A Plus 16S
41 = Activ A Plus 25S
P 02
00 =
01 =
factory set
02 =
03 =
00 =
01 =
P 03
00 =
(2) Max
01 =
(1) Med
02 =
Self regulat.
P 04
00 = No (factory set)
01 = Z1 with R.T., Z2
with R.C., Max. c.h.
ÀRZ WHPSHUDWXUH
02 = Z1 with R.T., Z2
with R.C., Min. c.h.
ÀRZ WHPSHUDWXUH
P 05
00 = G20 Natural
01 = G25
02 = --- --- --- ---
03 = --- --- --- ---
04 = G30 Butane
05 = G31 Propane
P 06
P 07
85÷45 (factory set 85 °C)
P 08
00 = No reset
04 = All parameters
return to factory set
with the exclusion of
P 01 and P 05
39 = All parameters return
to factory set included Pr
01 and Pr 05