4. Remove sanitizing solution source from the syrup system.
5. Allow sanitizing solution to remain in the syrup systems for not less than 10 or no more than 15-minutes
(max.) contact time.
STEP 4. WATER FLUSH SYSTEMS
WARNING: Flush sanitizing solution from the systems as instructed. Residual sanitizing
solution left in the systems could create a health hazard.
1. Fill tank (tank system) or a five-gallon container (bag-in-box system) with potable water.
Tank Systems.
A.
Connect tank containing potable water, pressurized at 60 to 80-psi, into one of the systems.
Bag-in-Box Syrup System.
B.
Place all bag-in-box syrup containers syrup outlet tubes in container containing potable water.
2. Flush sanitizing solution from the syrup system and the dispensing valve as follows:
A.
Place waste container under applicable dispensing valve.
B.
Activate the dispensing valve for one minute to purge all sanitizing solution out of the syrup system
and the dispensing valve.
C.
Continue to activate the dispensing valve in cycles ("ON" for 15-seconds, "OFF", then "ON" for
15-seconds). Repeat "ON" and "OFF" cycles for 15-cycles.
3. Repeat preceding steps to purge sanitizing solution out of the remaining syrup systems and
dispensing valves.
4. Remove potable water source from the syrup system.
STEP 5. PURGE WATER (RESTORE OPERATION)
Tank Systems.
1. Noting tanks CO
regulator pressure setting observed in step 4 preceding, readjust CO
2
observed pressure setting,
A.
Connect tanks containing the product onto the system.
Bag-in-Box Syrup System.
B.
Remove all bag valves from bag-in-box syrup containers outlet tubes connectors.
C.
Connect bag-in-box syrup containers into the syrup systems.
2. Place waste container under dispensing valves. Dispense from all dispensing valves to permit syrup to
purge all potable water from the syrup systems and the dispensing valves. Continue to dispense from the
dispensing valves until only syrup is dispensed from the syrup systems and valves.
WARNING: To avoid possible personal injury or property damage, do not attempt to
remove the syrup tank cover until CO
3. Dispose of waste sanitizing solution in sanitary sewer, not in storm drain, then thoroughly rinse inside and
outside of the container that was used for sanitizing solution to remove all sanitizing solution residue.
EIMI Cornelius Inc; 1994–2003
pressure has been released from the tank.
2
4
regulator to the
2
10/4/94
Revised 10/8/03