Syrup Flavor Change - Cornelius 326142000 Service Manual

(solid-state) post-mix dispenser two-flavor/hot-gas defrost with v3 electronics
Table of Contents

Advertisement

2. Slowly loosen CO
regulator assembly coupling nut allowing CO
2
regulator assembly from empty CO
3. Unfasten safety chain and remove empty CO
4. Position full CO
cylinder and secure with safety chain.
2
WARNING: To avoid personal injury and/or property damage, always secure CO
upright position with safety chain to prevent it from falling over. Should valve become
accidentally damaged or broken off, CO
5. Make sure gasket is in place inside CO
6. Open (counterclockwise) CO
to back-seat valve. (Back-seating valve prevents leakage around valve shaft).
7. Check CO
connections for leaks. Tighten loose connections.
2

SYRUP FLAVOR CHANGE

One or both syrup flavors can be changed at the same time. Perform flavor change on one system as follows:
1. Perform sanitizing procedure on syrup system syrup flavor change will be made on as instructed in
SERVICE AND MAINTENANCE SECTION.
IMPORTANT: The following CO
soft drink tank replacement or filling soft drink tank in place must be performed in order as follows:
To disconnect soft drink tank from Unit syrup system.
A.
Disconnect liquid disconnect from soft drink tank. NOTE - Disconnecting liquid disconnect
from soft drink tank first prevents syrup from backflowing through Unit syrup flow regulator
which may alter regulator adjustment.
B.
Second, disconnect CO
To connect soft drink tank into Unit syrup system.
C.
First, connect CO
D.
Second, connect liquid quick disconnect to soft drink tank.
2. First, pressurize soft drink tank containing new flavor syrup by connecting CO
Unit syrup inlet line to tank.
3. Press applicable ''FILL 1'' or ''FILL 2'' switch to fill applicable No. 1 or No. 2 syrup system syrup float switch
with syrup.
4. Press applicable ''AUTO BLEND 1'' or ''AUTO BLEND 2'' switch to fill applicable No. 1 or No. 2 system
product blender tank with product.
5. Press applicable ''AUTO 1'' or ''AUTO 2'' switch to start refrigeration system and beater in applicable No. 1
or No. 2 freeze cylinder.
CAUTION: Do not relieve freeze cylinder pressure too fast or product will foam excessively
in freeze cylinder and lose carbonation.
6. After carbonator water pump cycles off, intermittently pull and release applicable No. 1 or No. 2 freeze
cylinder faceplate relief valve. This bleeds CO
cylinder.
7. If necessary, adjust BRIX, product viscosity (product consistency), and product carbonation of dispensed
product as instructed.
cylinder.
2
cylinder.
2
2
regulator coupling nut, then install regulator on CO
2
cylinder valve slightly to allow lines to slowly fill with gas, the open valve fully
2
and liquid disconnects disconnecting and connecting procedure for
2
quick disconnect from soft drink tank.
2
quick disconnect to soft drink tank to pressurize tank.
2
from freeze cylinder and allows product to enter and fill
2
51
pressure to escape, then remove
2
cylinder can cause serious personal injury.
cylinder in
2
cylinder.
2
line to tank, then connect
2
326142000