GENERAL DESCRIPTION

This section gives the description, theory of operation, and design data for the FCB Solid-State Post-Mix
Two-Flavor Dispenser with Hot-Gas Defrost (hereafter referred to as a Unit).

UNIT DESCRIPTION

The Unit (see Figure NO TAG) consists basically of two freeze cylinders each containing an internal beater
driven by an electric motor, one refrigeration system with a 2-horsepower compressor, one carbonator which
feeds both carbonator-blender tanks, a timer-controlled automatic hot-gas defrost system to defrost the freeze
cylinders, and interconnecting tubing, components, and fittings necessary to regulate, transfer, and dispense
product. The components are attached to a steel frame and are enclosed in a steel cabinet. The cabinet panels
are easily removed to facilitate installation and service and maintenance. A transparent faceplate, with an
integral relief valve and a removable self-closing dispensing valve, is mounted on front of each freeze cylinder.
A removable drip tray, with cup rest, is located directly below the dispensing valves.
CAUTION: Before shipping, storing, or relocating Unit, syrup systems must be sanitized
and all sanitizing solution must be purged from syrup systems. All water must also be
purged from plain and carbonated water systems. A freezing ambient environment will
cause residual sanitizing solution or water remaining inside Unit to freeze resulting in damage to
internal components.

FIGURE 1. FCB (SOLID-STATE) POST-MIX TWO-FLAVOR DISPENSER

Part Number:
60 Hz Unit
50 Hz Unit

GENERAL INFORMATION

Table 1. Design Data
1
Table 2. Design Data
Part Number:
416120XXX
416120XXX
496120XXX
326142000