■ Amplifier Units
Item
Measurement period*1
Possible average count settings
Temperature characteristic
Linear output*2
Judgement outputs
(3 outputs: HIGH/PASS/LOW)*1
Laser OFF input, zero reset input,
timing input, reset input
Functions
Indications
Power supply voltage
Current consumption
Ambient temperature
Ambient humidity
Insulation resistance
Dielectric strength
Vibration resistance
(destruction)
Shock resistance
(destruction)
Connection method
Weight (packed state)
Materials
Accessories
*1. The response time for the first linear output or judgment output is calculated as follows (with fixed sensitivity): Measurement period × (Average
count setting + 1). The response time for the second and later outputs is the measurement period specified in the table.
*2. The output can be switched between a current output and voltage output using a switch on the bottom of the Amplifier Unit.
*3. Setting is possible via the monitor focus function.
*4. A Calculating Unit (ZX-CAL2) is required.
Model
ZX-LDA11-N
150 μs
1, 2, 4, 8, 16, 32, 64, 128, 256, 512, 1,024, 2,048, or 4,096
When connected to a Reflective Sensor Head: 0.01% FS/°C, When connected to a Through-beam Sensor
Head: 0.1% FS/°C
Current output: 4 to 20 mA/FS, Max. load resistance: 300 Ω
Voltage output: ±4 V (± 5 V, 1 to 5 V *3), Output impedance: 100 Ω
NPN open-collector outputs, 30 VDC, 50 mA max.
Residual voltage: 1.2 V max.
ON: Short-circuited with 0-V terminal or 1.5 V or less
OFF: Open (leakage current: 0.1 mA max.)
Measurement value display, present value/set value/light level/resolution display, scaling, display reverse,
display OFF mode, ECO mode, number of display digit changes, sample hold, peak hold, bottom hold,
peak-to-peak hold, self-peak hold, self-bottom hold, average hold, delay hold, intensity mode, zero reset,
initial reset, ON-delay timer, OFF-delay timer, one-shot timer, deviation, previous value comparison,
sensitivity adjustment, keep/clamp switch, direct threshold value setting, position teaching, 2-point
teaching, automatic teaching, hysteresis width setting, timing inputs, reset input, monitor focus, linear
output compensation, (A-B) calculations*4, (A+B) calculations*4, mutual interference*4, laser
deterioration detection, zero reset memory, zero reset display, key lock
Operation indicators: High (orange), pass (green), low (yellow), 7-segment main display (red), 7-segment
subdisplay (yellow), laser ON (green), zero reset (green), enable (green)
12 to 24 VDC ±10%, Ripple (p-p): 10% max.
140 mA max. with power supply voltage of 24 VDC (with Sensor connected)
Operating and storage: 0 to 50°C (with no icing or condensation)
Operating and storage: 35% to 85% (with no condensation)
20 MΩ min. at 500 VDC
1,000 VAC, 50/60 Hz for 1 min
10 to 150 Hz, 0.7-mm double amplitude 80 min each in X, Y, and Z directions
2
300 m/s
3 times each in six directions (up/down, left/right, forward/backward)
Prewired (standard cable length: 2 m)
Approx. 350 g
Case: PBT (polybutylene terephthalate), Cover: Polycarbonate
Instruction sheet
ZX Series (ZX-L-N)
ZX-LDA41-N
PNP open-collector outputs, 30 VDC, 50 mA max.
Residual voltage: 2 V max.
ON: Supply voltage short-circuited or supply voltage
within 1.5 V
OFF: Open (leakage current: 0.1 mA max.)
Smart Sensors (Laser Type)
5

Advertisement

Table of Contents
loading

Table of Contents