U407
Adjusting the writing timing (Duplex/Reversal)
(Message: Adjust Scanning Margin(DP))
Contents
Adjusts the writing timing when duplex printing.
Purpose
Adjusted when the back page image of duplex copying is printed in rotated 180 degrees from the scanner
reading image (image on the memory)
Precautions
Adjust this after finishing the following maintenance modes.
U034(P.1-3-36) > U402(P.1-3-123) > U66(P.1-3-47) >
U403(P.1-3-124) > U71(P.1-3-51) > U404(P.1-3-125) > U407
Adjustment
1.Press the [Start] key.
2.Press the [System Menu] key.
3.Place an original on the DP and press the [Start] key to make a test copy.
4.Press the [System Menu] key.
5.Select [Adj Data].
Items
Adj Data
6.By using the [+] [-] keys or the numeric keys, change the setting value.
For the copy example 1, increase the value.
For the copy example 2, decrease the value.
*: When the setting value is increased, the image moves forward, and it moves backward when the set-
ting value is decreased.
7.Press the [Start] key to set the setting value.
Completion
Press the [Stop] key.
*: The screen for selecting a maintenance item No. is displayed.
Y118240-1
Contents
Adjusts the leading edge timing when
writing the image in the memory
Leading edge registration of the copy image (+1.0/-1.5 mm or less)
Original
Figure 3-20
1-3-127
Setting range
-47 to 47
Copy
Copy
example 2
example 1
Initial
Data
setting
varia-
tion
0
1dot