Check and Top-Off Water Ice Bath

1. Remove the drip tray and lower splash panel.
Lower Splash Panel
Cup Rest
Drip Tray
Figure 38. Drip Tray and Cup Rest
If the Ice bath level is below the Full indicator, top it off with water. Refer to the Filling the Ice Bath previously covered in this
manual.
A
NNUALLY

Replace Pump Tubing and Clean Cabinet

A replacement pump tubing kit, part # 45098, is available. The kit consists of one pre-cut length of pump tubing, two white plastic
hose clamps, and instructions. Order two kits for 2-flavor or four kits for 4-flavor units.

Removing Pump Platform(s)

1. Remove the concentrate containers from the dispenser and place them in a refrigerator.
2. Remove the cabinet shelf that the concentrate containers sit on.
3. Flush the system prior to removing the pump platform (refer to the Daily). Remove the dispense nozzles and static
mixers.
4. Unplug the water line quick disconnect by pressing the gray button (See Figure 22).