Battery Critical Shutdown: 6.2V
l
Battery lifespan: 3-5 years
l
Operating Environmental Conditions
Temperature range: UL= 0°C to +49°C (32°F-120°F), EN= -10°C to 55°C (50°F-131°F)
l
Relative humidity: <93% non condensing
l
Alarm Transmitter Equipment (ATE) Specification
Communications over cellular or Ethernet
l
Supports SIA and Contact ID
l
Complies with TS203 021-1, -2, -3 Telecom equipment requirements and EN50136-1-1, EN50136-2-1, EN50136-2-3
l
ATS 2
Compliant with EN50136-1-1, EN50136-2-1 ATS2 requirements
l
System Supervision Features
The iotega continuously monitors a number of possible trouble conditions and provides audible and visual indication at the
keypad if a trouble is present. Trouble conditions include:
AC power failure
l
Zone trouble
l
Fire trouble
l
Communicator trouble
l
Low battery condition
l
RF jam
l
Failure to communicate
l
Module fault (supervisory or tamper)
l
Additional Features
2-way audio Talk/Listen support*
l
Audio verification*
l
Quick arming
l
User, partition, module, zone and system labels
l
* Not evaluated by UL.