Wireless Flood Configurations; Wireless Pir Cam Configurations - DSC iotega WS901 Reference Manual

Wireless security and automation system
Hide thumbs Also See for iotega WS901:
Table of Contents

Advertisement

Low Temperature Warning
This option is used to set the temperature threshold for activ-
ating the Low Temperature warning indicator. A low tem-
perature warning sounds an audible alert but does not send
a trouble to the central monitoring station.
This option is disabled by entering -999 or 999.
Default:
Valid range:
Low Temperature Alarm
This option is used to set the temperature threshold for activ-
ating the Low Temperature alarm.
This option is disabled by entering -999 or 999.
Default:
Valid range:
8.13 Wireless Flood Con-
figurations
The following sections are used for programming wireless
flood sensors.
Note: Wireless Flood feature was not evaluated by UL/ULC.
Device Enable/Disable
This option is used to enable and disable the wireless
device.
Default:
Valid range:
Device Partition Assignment
This option is used to assign the wireless device to an avail-
able partition.
Default:
Valid range:
Chime Tone
This option is used to select the tone emitted by the device
when the zone is tripped.
Default:
Disabled
Valid range:
Beeps, Bing Bing, Ding Dong, Alarm Tone
Zone Type
This programming section is used to program a zone type
for the device.
999
-999 to 999
999
-999 to 999
Enabled
Enabled/Disabled
Default: Interior Follower
Instant, Interior Follower, Interior Stay/Away, Delay
Valid
Stay/Away, 24 Hour Supervisory Buzzer, 24 Hour Non
range:
Alarm
Device Label
This section is used to program a custom label for the
device.
Default:
Valid range:
Zone Attribute
This option is used to customize zone operation. The fol-
lowing attributes are available for the temperature sensor:
Door Chime
Alarm Report
Burglary Verified
Transmission Delay
Bell Audible
Bell Steady
Bypass Enable
Force Arm
Swinger Shutdown
Two Way Audio
Talk Listen
Supervision
This section is used to enable/disable wireless supervision
of the device. Supervision monitors the presence of the wire-
less device on the alarm system.
Default:
Valid range:
1
1
8.14 Wireless PIR CAM Con-
figurations
The following sections are used to program wireless PIR
Camera motion detectors.
Device Enable/Disable
This option is used to enable and disable the wireless
device.
- 38 -
Zone ZZZ
32 character ASCII
Disabled
Enabled
Disabled
Enabled
Enabled (read-only)
Disabled (read-only)
Disabled (read-only)
Disabled (read-only)
Disabled (read-only)
Disabled (read-only)
Disabled (read-only)
Enabled
Enabled/Disabled

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iotega ws900ul

Table of Contents