DSC iotega WS901 Reference Manual page 35

Wireless security and automation system
Hide thumbs Also See for iotega WS901:
Table of Contents

Advertisement

Default:
Blank
Valid range:
32 character ASCII
Keypad Partition Assignment
This section is used to program the partition that the wireless
keypad is assigned to.
Default:
0 to 255
Fire Button Options
When this option is enabled, pressing and holding the Fire
[F] button on the wireless keypad for 2 seconds triggers a
Fire alarm. The system sounds 3 beeps to acknowledge the
valid alarm and the siren sounds with a pulsing tone. An
alarm reporting code is transmitted to the central monitoring
station.
Default:
Enabled
Valid range:
Enabled/Disabled
Auxiliary Button Options
When this option is selected, pressing and holding the Aux-
iliary [A] button on the wireless keypad for 2 seconds sends
an emergency alarm reporting code to the central mon-
itoring station. When the emergency reporting code is
received at the central monitoring station, the keypad beeps
10 times.
Default:
Enabled
Valid range:
Enabled/Disabled
Panic Button 
When this option is selected, pressing and holding the Panic
[P] button for 2 seconds on the wireless keypad sends an
emergency alarm reporting code to the central monitoring
station.
Default:
Enabled
Valid range:
Enabled/Disabled
Internal Buzzer Control
This option is used to set the volume level of the keypad's
internal buzzer. The volume ranges from lowest (1) to
highest (15). Programming (0) turns off the buzzer.
Note: Internal buzzer volume shall be at maximum setting
for UL/ULC.
1
1, 2, Both
Default:
Valid range:
Keypad Tamper
When this option is enabled, the wireless keypad tamper
switch generates tamper alarms and restores when activ-
ated.
Default:
Valid range:
Armed LED Power Save Option
This option is used to control the Armed LED on/off state. If
enabled, the Armed LED does not illuminate when the sys-
tem is armed to conserve battery life.
Default:
Valid range:
Auto Scroll Open Zones Option
When this option is enabled, the keypad automatically
scrolls through and displays all open zones.
Default:
Valid range:
Alarms Displayed While Armed Option
When this option is enabled, the keypad displays alarms on
affected zones while the system is armed.
If disabled, zones in alarm are not displayed while the sys-
tem is armed.
Default:
Valid range:
Power LED AC Present Option
When this option is enabled, the Power LED illuminates
when the iotega has electrical power.
When disabled, The Power LED illuminates when the iotega
does not have electrical power.
Default:
Valid range:
Auto Alarm Scroll Option
When this option is enabled, the keypad scrolls auto-
matically and displays all alarms when the bell is active or
when an alarm is in memory while armed.
- 32 -
7
0-15
Disabled
Enabled/Disabled
Disabled
Read-only
Enabled
Read-only
Enabled
Read-only
Enabled
Read-only