Melsec-Q Series (Serial Communications) - Omron NV3W Connection Manual

Programmable terminals
Hide thumbs Also See for NV3W:
Table of Contents

Advertisement

MELSEC-Q Series (Serial Communications)

1-3

MELSEC-Q Series (Serial Communications)

PLC Model Selection
Applicable Devices
Bit/word devices
Bit devices
Input relays
Output relays
Auxiliary relays
Latched relays
Annunciators
Edge relays
Link relays
Special relays
Link special relays
Step relays
Direct inputs
Direct outputs
Timer contacts
Timer coils
Accumulative timer contacts
Accumulative timer coils
Counter contacts
Counter coils
Word devices
Input relays
Output relays
Auxiliary relays
Latched relays
Annunciators
Edge relays
Link relays
Special relays
Link special relays
Step relays
Direct inputs
Direct outputs
Timer current values
Accumulative timer current values SN 000000 to SN 023087
Counter current values
Data registers
Link registers
Link special registers
File registers (for normal access) R 000000 to R 032767
File registers (for serial access)
Special registers
Note
6
Select Mitsubishi MELSEC-Q (Serial Communication) Series.
Select Mitsubishi MELSEC-Q (Serial Communication) Series even when con-
nected directly to the RS-232C port on the Q00 or Q01 CPU.
X 000000 to X 001FFF
Y 000000 to Y 001FFF
M 000000 to M 032767
L 000000 to L 032767
F 000000 to F 032767
V 000000 to V 032767
B 000000 to B 007FFF
SM 000000 to SM 002047
SB 000000 to SB 0007FF
S 000000 to S 008191
DX 000000 to DX 001FFF
DY 000000 to DY 001FFFF
TS 000000 to TS 023087
TC 000000 to TC 023087
SS 000000 to SS 023087
SC 000000 to SC 023087
CS 000000 to CS 023087
CC 000000 to CC 023087
X 000000 to X 001FF0
Y 000000 to Y 001FF0
M 000000 to M 032752
L 000000 to L 032752
F 000000 to F 032752
V 000000 to V 032752
B 000000 to B 007FF0
SM 000000 to SM 002032
SB 000000 to SB 0007F0
S 000000 to S 008176
DX 000000 to DX 001FF0
DY 000000 to DY 001FF0
TN 000000 to TN 023087
CN 000000 to CN 023087
D 000000 to D 025983
W 000000 to W 00657F
SW 000000 to SW 0007FF
ZR 000000 to ZR 0FE7FF
SD 000000 to SD 002047
(1) The maximum values that can be set by the PT are given.
(2) The addressable memory ranges depend on the model of PLC that is
used. Refer to the user manuals for your PLC for details.
No.
The first digit of the address must be 0.
The first digit of the address must be 0.
The address must be a multiple of 16.
The first digit of the address must be 0.
Section 1-3
Comments