Suzuki DF115BG 2021 Owner's Manual page 66

Table of Contents

Advertisement

STOPPING THE ENGINE
NOTE:
When it is necessary to stop the engine in an
emergency, pull the emergency stop switch lock
plate by pulling the emergency stop switch
cord.
If equipped with Keyless Start System:
To stop the engine:
1. Shift into "NEUTRAL".
2. After operating at full throttle, cool off the
engine a few minutes by allowing it to idle or
troll at low speed.
3. Quickly press the engine switch to shut off
all engines.
To stop each engine individually, press the
switch panel start/stop switch to shut off
each engine individually.
4. Turn the Keyless Start System to OFF
(locked) status by one of the following meth-
ods.
• Make sure that the keyless fob is within
the communication range of the keyless
control unit.
Press and hold the engine switch for at
least 3 seconds to set Keyless Start Sys-
tem to OFF state. (The buzzer is triggered
for one short beep.)
NOTE:
• While engines are running, press and hold
the engine switch for at least 2 seconds to
shut off all engines and set Keyless Start
System to OFF state.
• Keyless Start System automatically changes
to OFF state 15 minutes after the engines are
shut off.
• While the keyless fob is within the commu-
nication range of the keyless control unit,
press the lock button 1 on the keyless
fob.
The buzzer sounds three times to notify
that the Keyless Start System has been
turned OFF (locked).
63

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Df140bg 2021

Table of Contents