Suzuki DF115BG 2021 Owner's Manual page 25

Table of Contents

Advertisement

SETTING OF TILT UPPER LIMIT POSITION
If the outboard motor contacts the motor well of
the boat during full tilt up operation, the upper
limit setting should be reset.
Perform this set-up after the current position
setting has been canceled, as explained in the
following procedure.
CANCELING THE TILT UPPER POSITION
LIMIT SETTING
1. If equipped with Keyless Start System:
Press and hold the engine switch 1 for more
than two seconds to turn on the power.
If not equipped with Keyless Start System:
Turn the ignition key to the "ON" position.
2. Pull out the emergency stop switch lock
plate 2.
22
OFF
ON
START
3. Make sure that remote control handle is in
"NEUTRAL".
4. Confirm the select LED lights, if not, depress
the select switch on the remote control box.
Depress the "THROTTLE ONLY" button 3.
THROTTLE
ONLY
5. Move the control handle forward until the
caution buzzer sounds one time.
At this time, the message of "Set Limit
Angle" will appear on the gauge screen.
Press the "UP" side of the PTT switch for
three seconds and the buzzer will sound
twice briefly indicating the setting has been
canceled.
6. Return the throttle to the fully closed posi-
tion.
SETTING THE TILT UPPER POSITION
LIMIT
1. If equipped with Keyless Start System:
Press and hold the engine switch for more
than two seconds to turn on the power.
If not equipped with Keyless Start System:
Turn the ignition key to the "ON" position.
2. Press the "UP" side of the PTT switch so that
the optimum full tilt up position for the boat
can be obtained.
3. Pull out the emergency stop switch lock
plate.