f.
Release the sensor board cable from the retention clips (3) and routing channel that secure
the sensor board cable to the display back cover.
g.
Remove the sensor board cable.
The sensor board cable is available using spare part number N13578-001.
18.
To remove the sensor board:
a.
Remove the display assembly.
b.
Remove the display bezel.
c.
Remove the display panel assembly.
d.
Remove the sensor board cable.
e.
Release the LIF connectors (1) the microphone cables are connected to, and then disconnect
the microphone cables from the sensor board.
f.
Release the LIF connector (2) the webcam cable is connected to, and then disconnect the
webcam cable from the sensor board.
g.
Release the LIF connector (3) the ALS board cable is connected to, and then disconnect the
ALS board cable from the sensor board.
h.
Release the LIF connector (4) the motion board cable is connected to, and then disconnect the
motion board cable from the sensor board.