Lennox EL296UHVX Series Unit Information page 8

Hide thumbs Also See for EL296UHVX Series:
Table of Contents

Advertisement

BLOWER DATA
EL296UH070XV36B BLOWER PERFORMANCE (less filter)
BOTTOM RETURN AIR
0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range
Heating Speed
1
DIP Switch
Settings
+24%
+18%
+12%
+6%
Factory Default
–6%
–12%
–18%
Cooling Speed
1
DIP Switch
Low
Settings
+
600
Factory Default
555
500
Cooling and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific DIP Switch Settings.
1
Factory default setting.
2
NOTES - The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately 91% of the same second stage HEAT.
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan Only speed is selectable at 28% and 38% of the selected second stage cooling speed - minimum 250 cfm.
Lennox iHarmony
Zoning System Applications - Minimum blower speed is 250 cfm.
®
EL296UH070XV36B BLOWER MOTOR WATTS (COOLING)
Cooling Speed
1
DIP Switch
Settings
0
0.1
+ Setting
Low
22
Med-low
37
Cooling
Speed
Med-High 62
High
88
115 132 155 176 203 233 240 274 304 322 359 379 411 442 458 486 502 527 554
Factory Default
Low
16
Med-low
26
Cooling
Speed
Med-High 39
High
65
– Setting
Low
11
Med-low
21
Cooling
Speed
Med-High 35
High
43
First Stage Heating Speed - cfm
1095
1035
985
915
850
835
755
695
First Stage Cooling Speed - cfm
Medium-Low
Medium-High
740
665
600
Motor Watts @ Various External Static Pressures - in. wg.
First Stage
0.2
0.3
0.4
0.5
36
51
60
80
95
57
75
89
106 127 148 168 182 121 144 168 192 211 243 262 287 305 329 358
85
97
122 144 164 180 203 220 213 231 259 285 311 328 357 374 397 419 445
29
42
55
71
82
41
63
79
88
112 128 145 159
62
77
96
117 140 156 180 196 151 173 201 225 243 266 289 313 339 368 383
84
104 125 148 166 178 206 225 237 256 284 303 328 343 374 395 421 435 454
21
35
53
64
75
36
51
66
81
92
48
66
82
104 118 137 146 159 101 125 143 171 193 211 242 258 282 304 330
60
82
100 123 144 159 174 197 161 188 211 229 258 277 307 327 354 379 404
HEATING
COOLING
High
Low
2
840
970
860
770
855
810
680
790
705
0.6
0.7
0.8
0
0.1
101 117 138
68
88
98
112 120
52
69
89
108 135 151 174 198 223 247 268 288 298
82
95
113
34
50
107 127 141
64
85
Page 8
Second Stage Heating Speed - cfm
1220
1170
1120
1055
995
915
845
810
Second Stage Cooling Speed - cfm
Medium-Low
Medium-High
1060
960
840
Second Stage
0.2
0.3
0.4
0.5
0.6
105 129 152 169 198 214 231 244 274
86
107 122 146 165 183 199 212 229
67
86
106 121 141 159 174 186 201
100 114 145 160 182 206 219 237 251
High
2
1215
1365
1130
1265
1005
1140
0.7
0.8
0.9
1.0