BLOWER DATA
EL296UH090XV36C BLOWER PERFORMANCE (less filter)
BOTTOM RETURN AIR
0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range
Heating Speed
1
DIP Switch
Settings
+24%
+18%
+12%
+6%
Factory Default
–6%
–12%
–18%
Cooling Speed
1
DIP Switch
Low
Settings
+
625
Factory Default
565
520
Cooling and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific DIP Switch Settings.
1
Factory default setting.
2
NOTES - The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately 91% of the same second stage HEAT.
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan Only speed is selectable at 28% and 38% of the selected second stage cooling speed - minimum 250 cfm.
Lennox iHarmony
Zoning System Applications - Minimum blower speed is 250 cfm.
®
EL296UH090XV36C BLOWER MOTOR WATTS (COOLING)
Cooling Speed
1
DIP Switch
Settings
0
0.1
+ Setting
Low
19
Med-low
35
Cooling
Speed
Med-High 51
High
69
Factory Default
Low
14
Med-low
29
Cooling
Speed
Med-High 39
High
46
– Setting
Low
11
Med-low
23
Cooling
Speed
Med-High 24
High
33
First Stage Heating Speed - cfm
1215
1140
1100
1020
965
915
850
805
First Stage Cooling Speed - cfm
Medium-Low
Medium-High
710
670
610
Motor Watts @ Various External Static Pressures - in. wg.
First Stage
0.2
0.3
0.4
0.5
33
51
67
81
97
52
76
90
108 130 146 166 185
70
92
117 138 155 181 199 219 146 170 199 223 246 277 303 329 357 379 399
94
113 133 152 177 194 222 246 225 250 277 308 329 362 391 411 442 465 489
31
44
59
75
88
46
63
80
95
114 133 146 164
56
78
97
117 137 155 175 192 102 127 152 175 202 228 246 279 306 328 345
68
86
111 126 154 174 194 214 167 184 218 253 272 301 332 360 381 402 421
27
39
57
70
84
39
53
71
87
103 118 133 148
43
56
79
97
111 129 149 165
51
69
94
111 131 150 170 186 112 134 160 186 220 236 264 293 311 335 363
HEATING
COOLING
High
Low
2
830
950
875
760
860
800
685
785
720
0.6
0.7
0.8
0
0.1
113 128 144
47
64
87
114 130 158 184 205 227 252 278 301 321
104 125 137
37
54
65
87
99
113 131
26
45
44
60
75
101 117 140 160 182 215 235 255 275 296
Page 11
Second Stage Heating Speed - cfm
1300
1240
1170
1115
1070
970
925
855
Second Stage Cooling Speed - cfm
Medium-Low
Medium-High
1040
945
840
Second Stage
0.2
0.3
0.4
0.5
0.6
90
111 127 153 174 193 215 234 250
74
94
114 135 152 175 187 209 223
108 130 152 173 196 222 236 262 283
61
81
96
118 134 152 169 189 205
85
107 127 150 169 186 207 226 247
High
2
1210
1360
1100
1245
970
1115
0.7
0.8
0.9
1.0

Advertisement

Table of Contents
loading

Table of Contents