BLOWER DATA
EL296UH070XV36B BLOWER PERFORMANCE (less filter)
SINGLE SIDE RETURN AIR WITH OPTIONAL RETURN AIR BASE
0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range
Heating Speed
1
DIP Switch
Settings
+24%
+18%
+12%
+6%
Factory Default
–6%
–12%
–18%
Cooling Speed
1
DIP Switch
Low
Settings
+
595
Factory Default
520
490
Cooling and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific DIP Switch Settings.
1
Factory default setting.
2
NOTES - The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately 91% of the same second stage HEAT.
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan Only speed is selectable at 28% and 38% of the selected second stage cooling speed - minimum 250 cfm.
Lennox iHarmony
Zoning System Applications - Minimum blower speed is 250 cfm.
®
EL296UH070XV36B BLOWER MOTOR WATTS (COOLING)
Cooling Speed
1
DIP Switch
Settings
0
0.1
+ Setting
Low
18
Med-low
34
Cooling
Speed
Med-High 63
High
88
107 131 148 175 192 217 235 253 261 281 312 346 382 402 430 465 489 506 533
Factory Default
Low
12
Med-low
25
Cooling
Speed
Med-High 41
High
63
– Setting
Low
9
Med-low
16
Cooling
Speed
Med-High 28
High
46
First Stage Heating Speed - cfm
1070
1020
955
895
850
795
745
690
First Stage Cooling Speed - cfm
Medium-Low
Medium-High
715
655
595
Motor Watts @ Various External Static Pressures - in. wg.
First Stage
0.2
0.3
0.4
0.5
32
46
61
76
89
52
69
86
104 126 141 160 174 109 131 150 179 204 219 239 268 283 313 335
82
98
115 138 153 173 187 209 177 197 227 246 273 311 328 354 383 402 408
25
37
55
66
82
40
55
74
89
109 120 136 150
61
75
98
115 135 151 173 189 129 150 177 198 227 247 272 301 324 332 369
86
99
122 139 159 180 204 216 209 227 254 282 298 324 341 364 395 413 428
20
35
48
59
75
32
45
62
75
90
43
63
77
98
115 132 145 162
61
86
100 121 136 153 172 193 142 163 187 216 236 261 279 301 325 356 375
HEATING
COOLING
High
Low
2
815
950
855
755
840
790
670
745
720
0.6
0.7
0.8
0
0.1
104 115 133
64
83
94
105 121
43
61
76
96
86
94
110
29
43
103 119 138
56
71
88
107 129 154 183 204 214 245 263 281 308
Page 10
Second Stage Heating Speed - cfm
1205
1150
1100
1035
965
905
845
790
Second Stage Cooling Speed - cfm
Medium-Low
Medium-High
1045
945
845
Second Stage
0.2
0.3
0.4
0.5
0.6
95
120 141 159 175 203 208 234 246
76
99
121 133 162 169 189 211 224
112 138 162 186 207 232 243 262 281
63
84
99
113 131 144 164 185 197
101 112 131 158 168 184 207 235 245
High
2
1205
1350
1090
1255
985
1130
0.7
0.8
0.9
1.0