SP ECIF ICATIONS
Gas
Heating
Performance
High
Fire
Low
Fire
High static - in. w.g.
Connections
in.
Condensate Drain Trap (PVC pipe) - i.d.
with field supplied (PVC coupling) - o.d.
Indoor
Wheel nominal diameter x width - in.
Blower
Electrical Data
Shipping Data
NOTE - Filters and provisions for mounting are not furnished and must be field provided.
Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized
1
furnaces.
Model No.
AFUE
1
Input - Btuh
Output - Btuh
Temperature rise range - °F
Gas Manifold Pressure (in. w.g.)
Nat. Gas / LPG/Propane
Input - Btuh
Output - Btuh
Temperature rise range - °F
Gas Manifold Pressure (in. w.g.)
Nat. Gas / LPG/Propane
Heating
Cooling
Intake / Exhaust Pipe (PVC)
Gas pipe size IPS
with furnished 90° street elbow
Motor output - hp
Tons of add-on cooling
Air Volume Range - cfm
Voltage
Blower motor full load amps
Maximum overcurrent protection
lbs. - 1 package
EL296UH110XV60C
96%
110,000
106,000
45 - 75
3.5 / 10.0
72,000
70,000
35 - 65
1.7 / 4.9
0.8
1.0
2 / 2
1/2
3/4
3/4 slip x 3/4 Mipt
3/4 slip x 3/4 MPT
11 x 11
1
3-5
850 - 2125
120 volts - 60 hertz - 1 phase
12.8
20
174
Page 3
EL296UH135XV60D
96%
132,000
126,000
55 - 85
3.5 / 10.0
86,000
84,000
40 - 70
1.7 / 4.9
0.8
1.0
2 / 2
1/2
3/4
3/4 slip x 3/4 Mipt
3/4 slip x 3/4 MPT
11 x 11
1
3-5
950 - 2250
12.8
20
188