BLOWER DATA
EL296UH110XV60C BLOWER PERFORMANCE (less filter)
BOTTOM RETURN AIR
0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range
Heating Speed
1
DIP Switch
Settings
+24%
+18%
+12%
+6%
Factory Default
–6%
–12%
–18%
Cooling Speed
1
DIP Switch
Low
Settings
+
1060
Factory Default
970
885
Cooling and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific DIP Switch Settings.
1
Factory default setting.
2
NOTES - The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately 91% of the same second stage HEAT.
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan Only speed is selectable at 28% and 38% of the selected second stage cooling speed - minimum 450 cfm.
Lennox iHarmony
Zoning System Applications - Minimum blower speed is 450 cfm.
®
EL296UH110XV60C BLOWER MOTOR WATTS (COOLING)
Cooling Speed
1
DIP Switch
Settings
0
0.1
+ Setting
Low
81
113 135 165 200 228 251 280 315 220 254 300 346 385 432 472 511 560 600 610
Med-low 119 147 179 210 241 273 309 331 358 345 386 414 475 516 547 594 637 681 714 748
Cooling
Speed
Med-High 157 191 225 265 304 331 377 405 435 492 536 573 623 666 711 761 804 842 891 918
High
220 254 300 346 385 432 472 511 560 675 699 767 839 876 915 973 1033 1062 1115 1134
Factory Default
Low
60
Med-low
81
108 147 173 195 231 257 288 326 232 263 314 353 412 445 490 516 557 596 649
Cooling
Speed
Med-High 122 145 182 215 246 286 306 333 360 372 401 449 498 541 577 643 672 695 744 765
High
163 196 231 266 309 348 388 421 451 497 539 579 646 681 734 773 817 851 904 957
– Setting
Low
45
Med-low
56
Cooling
Speed
Med-High 80
114 141 161 203 230 256 294 318 248 274 324 386 416 470 494 539 583 620 652
High
124 146 189 215 245 279 316 331 373 377 413 457 502 548 583 629 684 705 753 783
First Stage Heating Speed - cfm
1385
1475
1355
1370
1200
1140
1070
980
First Stage Cooling Speed - cfm
Medium-Low
Medium-High
1245
1145
1025
Motor Watts @ Various External Static Pressures - in. wg.
First Stage
0.2
0.3
0.4
0.5
88
114 137 167 187 219 244 276 163 196 231 266 309 348 388 421 451 489 512
62
96
116 132 153 179 199 227 124 146 189 215 245 279 316 331 373 396 423
85
115 134 159 185 215 251 270 163 195 243 270 314 353 397 414 470 496 535
HEATING
COOLING
High
Low
2
1345
1545
1560
1265
1395
1405
1110
1250
1270
0.6
0.7
0.8
0
0.1
Page 22
Second Stage Heating Speed - cfm
1965
1880
1790
1725
1630
1550
1460
1345
Second Stage Cooling Speed - cfm
Medium-Low
Medium-High
1740
1565
1425
Second Stage
0.2
0.3
0.4
0.5
0.6
High
2
1930
2125
1775
1945
1610
1770
0.7
0.8
0.9
1.0