Protect Level - Omron E5 Z Series Manual

Digital temperature controllers
Table of Contents

Advertisement

Protect Level

Operation/adjustment protection
Restricts displaying and modifying menus in operation,
adjustment, and manual control levels.
Initial setting/communications protection
This protect level restricts movement to the initial setting,
communications setting, and advanced function setting levels.
Setting change protection
Protects changes to setups by operating the front panel
keys.
Operation/Adjustment Protection
The following table shows the relationship between set values and
the range of protection.
Level
Operation level
PV
PV/SP
Other
Adjustment level
When this parameter is set to "0," parameters are not protected.
Default setting: 0
:
Can be displayed and changed
❍: Can be displayed
X : Cannot be displayed and move to other levels not possible
Initial Setting/Communications Protection
This protect level restricts movement to the initial setting level, com-
munications setting level and advanced function setting level.
Set
Initial setting level Communications
value
0
1
2
X
Default setting: 1
❍: Move to other levels possible
X: Move to other levels not possible
Setting Change Protection
This protect level protects setup from being changed by operating
the keys on the front panel.
Set value
OFF
Setup can be changed by key operation.
ON
Setup cannot be changed by key operation.
(The protect level, can be changed.)
Default setting: OFF
26
Digital Temperature Controllers
Set value
0
1
2
X
X
X
Advanced
setting level
function setting
level
X
X
X
Description
E5AZ/E5EZ/E5CZ
3
X
X

Advertisement

Table of Contents
loading

This manual is also suitable for:

E5azE5ezE5czE5ez-prr

Table of Contents